@@ -156,7 +156,7 @@ namespace UAS_PLCDataReader
|
|
|
GridCommandSetting.GetDataSQL = "select 0 CHECKEDCOLUMN,dc_id,dc_code,dc_name,dc_type,case when dc_type='INQTY' then '投入' when dc_type='OUTQTY' then '产出' when dc_type='TEMPERATURE' then '温度' when dc_type='PARAM1' then '参数1' when dc_type='PARAM2' then '参数2' when dc_type='PARAM3' then '参数3' end dc_typename,dc_value,dc_dataindex,dc_sendcoding,dc_receivecoding,db_name,dc_man,dc_date from devicecommand left join devicebrand on db_code=dc_debrand".ToUpper();
|
|
|
GridCommandSetting.TableName = "devicecommand";
|
|
|
GridCommandSetting.ID = "dc_id";
|
|
|
- GridCommandSetting.InsertSQL = "insert into devicecommand(dc_id,dc_code,dc_name,dc_value,dc_debrand,dc_sendcoding,dc_receivecoding,dc_man,dc_date,dc_dataindex) values(devicecommand_seq.nextval,:dc_code,:dc_name,:dc_value,'" + BaseUtil.GetComboxEditValue(Brand) + "',:dc_sendcoding,:dc_receivecoding,'" + User.UserName + "',sysdate,:dc_dataindex)";
|
|
|
+ GridCommandSetting.InsertSQL = "insert into devicecommand(dc_id,dc_code,dc_name,dc_value,dc_debrand,dc_sendcoding,dc_receivecoding,dc_man,dc_date,dc_dataindex,dc_type) values(devicecommand_seq.nextval,:dc_code,:dc_name,:dc_value,'" + BaseUtil.GetComboxEditValue(Brand) + "',:dc_sendcoding,:dc_receivecoding,'" + User.UserName + "',sysdate,:dc_dataindex,:dc_type)";
|
|
|
ButtonSaveCommand.Grid = GridCommandSetting;
|
|
|
ButtonDeleteCommand.Grid = GridCommandSetting;
|
|
|
ButtonNewCommand.Grid = GridCommandSetting;
|
|
|
@@ -352,7 +352,7 @@ namespace UAS_PLCDataReader
|
|
|
/// <param name="e"></param>
|
|
|
private void ButtonSaveCommand_Click(object sender, EventArgs e)
|
|
|
{
|
|
|
- GridCommandSetting.InsertSQL = "insert into devicecommand(dc_id,dc_code,dc_name,dc_value,dc_debrand,dc_sendcoding,dc_receivecoding,dc_man,dc_date,dc_dataindex) values(devicecommand_seq.nextval,:dc_code,:dc_name,:dc_value,'" + BaseUtil.GetComboxEditValue(Brand) + "',:dc_sendcoding,:dc_receivecoding,'" + User.UserName + "',sysdate,:dc_dataindex)";
|
|
|
+ GridCommandSetting.InsertSQL = "insert into devicecommand(dc_id,dc_code,dc_name,dc_value,dc_debrand,dc_sendcoding,dc_receivecoding,dc_man,dc_date,dc_dataindex,dc_type) values(devicecommand_seq.nextval,:dc_code,:dc_name,:dc_value,'" + BaseUtil.GetComboxEditValue(Brand) + "',:dc_sendcoding,:dc_receivecoding,'" + User.UserName + "',sysdate,:dc_dataindex,:dc_type)";
|
|
|
ButtonSaveCommand.DoSaveAfterHandler(true);
|
|
|
sql.Clear();
|
|
|
sql.Append("update devicecommand set dc_man='" + User.UserName + "',dc_date=sysdate where dc_id=:dc_id");
|